Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Samples
The supplier provides sample based customization services
to see all verified strength labels (9)
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
  • Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Workshop Corner
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
YJV YJLV
Application
Overhead
Conductor Material
Copper
Sheath Material
PVC
Insulation Material
XLPE
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CE, CCC, RoHS
Brand
Qif
Core Number
1, 2, 3, 4, 3+1, 5, 4+1, 3+2
Nominal Cross Section of Conductor
1.5~800mm²
Other Types
Zryjv32, Nhyjv32
Warranty
100% Qualified
Armored Layer
Steel Wire
Packing Material
Wooden Drum
Insulation Color
Black, Red, Green, Orange
Transport Package
Standard Export Packing
Specification
4*95
Trademark
QIF
Origin
China
HS Code
854449210
Production Capacity
500000m/Month

Product Description

Product Description

Structure
1.Conductor:Class 1,Class 2,Class 5 Copper conductor
2.Insulation:Cross linked polyethylene (XLPE)
3.Filler:Non-hygroscopic material
4.Binder tape:Non-hygroscopic material tape/Non-woven tape
5. Sheath:Polyvinyl chloride compound (PVC)

Application
To be used for main power supply, In low voltage distribution power networks, industrial installations, in buildings and operation stations. fixed installation in the ground or in concrete, in the cable trenches or cable, ducts, indoor or outdoor areas, in dry or wet locations.

Cross Section
1C1.5~1C800mm2
2C1.5~2C400mm2
3C1.5~3C400mm2
4C1.5~4C400mm2
5C1.5~5C400mm2
2C+E2.5~2C+E400mm2
3C+E2.5~3C+E400mm2
4C+E2.5~4C+E400mm2
 
Temperature characteristics             
Conductor operating temperature: -15ºC~90ºC                  
Min. temperatrue laying condition: 0ºC
Conductor emergency operating temperature: 105ºC
Conductor short-circuit operating temperature (5s): 250ºC

Detailed Photos

 

Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
 
Product Parameters

 

Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
1×1.5 1.38 0.7 1.4 5.7 45
1×2.5 1.76 0.7 1.4 6.1 57
1×4 2.22 0.7 1.4 6.6 74
1×6 2.74 0.7 1.4 7.1 96
1×10 4 0.7 1.4 8.3 140
1×16 5 0.7 1.4 9.3 201
1×25 6.1 0.9 1.4 10.8 298
1×35 7.2 0.9 1.4 11.9 392
1×50 8.4 1 1.4 13.3 513
1×70 10 1.1 1.4 15. 1 718
1×95 12 1.1 1.5 17.3 977
1×120 13 1.2 1.5 18.5 1209
1×150 14.9 1.4 1.6 21 1498
1×185 16.5 1.6 1.7 23.3 1858
1×240 18.4 1.7 1.8 25.6 2412
1×300 21 1.8 1.8 28.4 2992
1×400 23.4 2 2 32 3843
1×500 26.6 2.2 2.1 35.4 4893
1×630 30 2.4 2.2 39.4 6228
1×800 34 2.6 2.3 44. 1 7922
1×1000 38.2 2.8 2.5 49. 1 9913
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
2×1.5 1.38 0.7 1.8 10 111
2×2.5 1.76 0.7 1.8 10.8 139
2×4 2.22 0.7 1.8 11.7 178
2×6 2.74 0.7 1.8 12.7 228
2×10 4 0.7 1.8 15.2 331
2×16 5 0.7 1.8 17.2 466
2×25 6.1 0.9 1.8 20.2 685
2×35 7.2 0.9 1.8 22.4 894
2×50 8.4 1 1.8 25.4 1173
2×70 10 1.1 1.8 29 1626
2×95 12 1.1 2 33.4 2212
2×120 13 1.2 2.1 36 2731
2×150 14.9 1.4 2.2 40.9 3390
2×185 16.5 1.6 2.3 45. 1 4186
2×240 18.4 1.7 2.5 49.8 5410
2×300 21 1.8 2.7 55.8 6752
2×400 23.4 2 2.9 62.6 8625
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
3×1.5 1.38 0.7 1.8 10.4 131
3×2.5 1.76 0.7 1.8 11.3 170
3×4 2.22 0.7 1.8 12.3 224
3×6 2.74 0.7 1.8 13.4 293
3×10 4 0.7 1.8 16 431
3×16 5 0.7 1.8 18.2 621
3×25 6.1 0.9 1.8 21.5 928
3×35 7.2 0.9 1.8 23.9 1225
3×50 8.4 1 1.8 27. 1 1615
3×70 10 1.1 1.9 31.2 2273
3×95 12 1.1 2 35.7 3083
3×120 13 1.2 2.1 38.5 3826
3×150 14.9 1.4 2.3 43.9 4762
3×185 16.5 1.6 2.4 48.5 5894
3×240 18.4 1.7 2.6 53.5 7644
3×300 21 1.8 2.8 59.9 9538
3×400 23.4 2 3.1 67.5 12238
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
4×1.5 1.38 0.7 1.8 11.2 157
4×2.5 1.76 0.7 1.8 12.2 206
4×4 2.22 0.7 1.8 13.3 276
4×6 2.74 0.7 1.8 14.5 365
4×10 4 0.7 1.8 17.5 544
4×16 5 0.7 1.8 19.9 791
4×25 6.1 0.9 1.8 23.6 1191
4×35 7.2 0.9 1.8 26.4 1586
4×50 8.4 1 1.9 30 2101
4×70 10 1.1 2 34.6 2965
4×95 12 1.1 2.1 39.7 4031
4×120 13 1.2 2.3 43 5027
4×150 14.9 1.4 2.4 48.8 6229
4×185 16.5 1.6 2.6 54. 1 7737
4×240 18.4 1.7 2.8 59.6 10038
4×300 21 1.8 3 66.8 12528
4×400 23.4 2 3.3 75.2 16068

Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
5×1.5 1.38 0.7 1.8 12 183
5×2.5 1.76 0.7 1.8 13. 1 244
5×4 2.22 0.7 1.8 14.4 330
5×6 2.74 0.7 1.8 15.7 440
5×10 4 0.7 1.8 19 660
5×16 5 0.7 1.8 21.7 965
5×25 6.1 0.9 1.8 26 1468
5×35 7.2 0.9 1.8 29 1952
5×50 8.4 1 2 33.2 2606
5×70 10 1.1 2.1 38.3 3680
5×95 12 1.1 2.3 44. 1 5022
5×120 13 1.2 2.4 47.5 6237
5×150 14.9 1.4 2.6 54.2 7756
5×185 16.5 1.6 2.8 60 9627
5×240 18.4 1.7 3 66. 1 12492
5×300 21 1.8 3.2 74. 1 15590
5×400 23.4 2 3.6 83.6 20029
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
3×2.5+ 1×1.5 1.76/ 1.38 0.7/0.7 1.8 11.9 193
3×4+ 1×2.5 2.22/ 1.76 0.7/0.7 1.8 13 258
3×6+ 1×4 2.74/2.22 0.7/0.7 1.8 14.2 343
3×10+ 1×6 4.0/2.74 0.7/0.7 1.8 16.7 498
3×16+ 1×10 5.0/4.0 0.7/0.7 1.8 19.2 727
3×25+ 1×16 6. 1/5.0 0.9/0.7 1.8 22.6 1088
3×35+ 1×16 7.2/5.0 0.9/0.7 1.8 24.8 1385
3×50+ 1×25 8.4/6. 1 1.0/0.9 1.8 28.2 1860
3×70+ 1×35 10.0/7.2 1. 1/0.9 1.9 32.4 2606
3×95+ 1×50 12.0/8.4 1. 1/ 1.0 2.1 37.3 3546
3×120+ 1×70 13.0/ 10.0 1.2/ 1. 1 2.2 40.7 4495
3×150+ 1×70 14.9/ 10.0 1.4/ 1. 1 2.3 45.5 5406
3×185+ 1×95 16.5/ 12.0 1.6/ 1. 1 2.5 50.6 6799
3×240+ 1×120 18.4/ 13.5 1.7/ 1.2 2.7 55.6 8771
3×300+ 1×150 21.0/ 14.9 1.8/ 1.4 2.9 62.6 10949
3×400+ 1×185 23.4/ 16.5 2.0/ 1.6 3.1 69.9 13938
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
3×2.5+2×1.5 1.76/ 1.38 0.7/0.7 1.8 12.7 220
3×4+2×2.5 2.22/ 1.76 0.7/0.7 1.8 13.9 296
3×6+2×4 2.74/2.22 0.7/0.7 1.8 15.2 396
3×10+2×6 4.0/2.74 0.7/0.7 1.8 17.8 572
3×16+2×10 5.0/4.0 0.7/0.7 1.8 20.7 844
3×25+2×16 6. 1/5.0 0.9/0.7 1.8 24.5 1271
3×35+2×16 7.2/5.0 0.9/0.7 1.8 26.5 1564
3×50+2×25 8.4/6. 1 1.0/0.9 1.9 30.6 2151
3×70+2×35 10.0/7.2 1. 1/0.9 2 35 2994
3×70+2×50 10.0/8.4 1. 1/ 1.0 2.1 36.2 3229
3×95+2×50 12.0/8.4 1. 1/ 1.0 2.2 40.3 4065
3×120+2×70 13.0/ 10.0 1.2/ 1. 1 2.3 44.2 5222
3×150+2×70 14.9/ 10.0 1.4/ 1. 1 2.4 48.7 6135
3×150+2×95 14.9/ 12.0 1.4/ 1. 1 2.5 50. 1 6608
3×185+2×95 16.5/ 12.0 1.6/ 1. 1 2.6 54.4 7794
3×240+2×120 18.4/ 13.5 1.7/ 1.2 2.8 59.7 10013
3×300+2×150 21.0/ 14.9 1.8/ 1.4 3 67.2 12483
3×400+2×185 23.4/ 16.5 2.0/ 1.6 3.3 75.4 15892
 
Size mm2 Conductor   Diameter mm Insulation   thickness mm Sheath thickness mm Approx. diameter mm Approx. weight kg/km
4×2.5+ 1×1.5 1.76/ 1.38 0.7/0.7 1.8 12.9 232
4×4+ 1×2.5 2.22/ 1.76 0.7/0.7 1.8 14. 1 312
4×6+ 1×4 2.74/2.22 0.7/0.7 1.8 15.4 417
4×10+ 1×6 4.0/2.74 0.7/0.7 1.8 18.4 616
4×16+ 1×10 5.0/4.0 0.7/0.7 1.8 21.2 905
4×25+ 1×16 6. 1/5.0 0.9/0.7 1.8 25.2 1368
4×35+ 1×16 7.2/5.0 0.9/0.7 1.8 27.7 1756
4×50+ 1×25 8.4/6. 1 1.0/0.9 1.9 31.7 2367
4×70+ 1×35 10.0/7.2 1. 1/0.9 2.1 36.7 3342
4×95+ 1×50 12.0/8.4 1. 1/ 1.0 2.2 42 4528
4×120+ 1×70 13.0/ 10.0 1.2/ 1. 1 2.4 45.9 5736
4×150+ 1×70 14.9/ 10.0 1.4/ 1. 1 2.5 51.3 6935
4×185+ 1×95 16.5/ 12.0 1.6/ 1. 1 2.7 57. 1 8701
4×240+ 1×120 18.4/ 13.5 1.7/ 1.2 2.9 62.8 11242
4×300+ 1×150 21.0/ 14.9 1.8/ 1.4 3.1 70.5 14021
4×400+ 1×185 23.4/ 16.5 2.0/ 1.6 3.4 79.2 17920
 
Workshop Corner
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Packaging & Shipping
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables
Custom Multiple Core Low and Medium Voltage Electric Cable Copper/Aluminum Insulated PVC Power Cables

 

FAQ

How can I get some samples?

We provide free sample and will courier to you by DHL, FEDEX, UPS, TNT, etc. swiftly according to your requirements.


How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.   
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..

What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.


What's the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement

What's the lead time?
Usually 10-30 working days.

Welcome your inquiry and email soon......

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now