XLPE insulated underground power cables for rated voltages up to 0.6/1 kV are fit for AC 50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordant with GB/T12706-2008 ( Power cables extruded insulation and their accessories of rated voltagesl kV(Umz1.2kV)up to ) and IEC-60502-1 :2004 ( Extruded insulation power cables and appendites for rated voltages 1kV up to 30kV)
Production Range
Type |
Description |
Scope of Application |
YJV YJLV Z(K)-YJV Z(K)-YJLV |
Cu or AI conductor XLPE insulated PVC sheathed power cable |
Installed indoors or outdoors. In case unable to bear external mechanical forces but tractive force during laying, single core cable in magnetic duct is not permissible. |
YJV22 YJLV22 Z(K)-YJV22 Z(K)-YJLV22 |
Cu or AI Conductor XLPE Insulated PVC Sheathed Steel Tape Armoured Power Cable |
For laying in ground able to bear external mechanical forces, but unable to bear large pulling force. |
YJV32 YJLV32 Z(K)-YJV32 Z(K)-YJLV32 |
Cu or AI Conductor XLPE Insulated PVC Sheathed Fine Steel Wire Armoured Power Cable |
For laying in water or able to bear external mechanical forces and equal pulling force. |
Operating Characteristics
1. Rated Voltage: 0.6/1kV
2. Max.permissible operating temperature of conductor is 90ºC.
3. Conductor short-circuit temperature shall not exceed 250ºC Max. sustaining period shall not exceed 5 seconds.
4. Bending Radius
Bending radius of single core cable:20(D+d)±5%
Bending radius of multi core cable:15(D+d)±5%
D-Actual outer diameter of cable sample(mm);
d-Actual diameter of the conductor(mm).
5. No restriction of level difference along the route for installation.
6. Installation temperature shall be heated when ambient temperature is below 0ºC
0.6/1kV single-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV62 |
YJLV62 |
YJV72 |
YJLV72 |
||||
1*4 |
6.8 |
87 |
64 |
/ |
/ |
/ |
/ |
/ |
/ |
1*6 |
7.2 |
110 |
71 |
/ |
/ |
/ |
/ |
/ |
/ |
1*10 |
8.0 |
165 |
96 |
/ |
/ |
/ |
/ |
/ |
/ |
1*16 |
8.9 |
220 |
123 |
/ |
/ |
/ |
/ |
/ |
/ |
1*25 |
10.4 |
345 |
172 |
14.3 |
451 |
293 |
17.6 |
780 |
622 |
1*35 |
11.5 |
424 |
212 |
15.5 |
564 |
345 |
18.6 |
910 |
691 |
1*50 |
13.0 |
555 |
274 |
17.2 |
721 |
424 |
20.6 |
1125 |
828 |
1*70 |
14.0 |
770 |
354 |
19.0 |
951 |
522 |
22.0 |
1373 |
944 |
1*95 |
16.4 |
1040 |
474 |
21.3 |
1252 |
657 |
24.3 |
1904 |
1309 |
1*120 |
17.8 |
1290 |
565 |
22.9 |
1515 |
763 |
26.8 |
2241 |
1489 |
1*150 |
20.6 |
1590 |
690 |
24.9 |
1822 |
898 |
28.8 |
2815 |
1891 |
1*185 |
22.5 |
1944 |
854 |
27.1 |
2229 |
1070 |
31.2 |
31403 |
1981 |
1*240 |
24.9 |
2510 |
1092 |
30.2 |
2847 |
1323 |
33.3 |
3890 |
2366 |
1*300 |
27.3 |
3176 |
1345 |
35.2 |
3867 |
1956 |
40.0 |
5165 |
3254 |
1*400 |
34.1 |
4160 |
1680 |
38.8 |
4802 |
2358 |
42.9 |
6836 |
4392 |
1*500 |
39.0 |
5302 |
2124 |
43.0 |
6059 |
2881 |
48.5 |
8100 |
4922 |
0.6/1kV 2-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
2*4 |
12.2 |
224 |
175 |
15.9 |
351 |
302 |
/ |
/ |
/ |
2*6 |
13.2 |
278 |
204 |
16.9 |
415 |
340 |
/ |
/ |
/ |
2*10 |
15.8 |
397 |
273 |
19.5 |
558 |
434 |
/ |
/ |
/ |
2*16 |
17.9 |
545 |
346 |
21.6 |
726 |
527 |
/ |
/ |
/ |
2*25 |
16.6 |
609 |
361 |
20.0 |
775 |
527 |
25.8 |
1643 |
1331 |
2*35 |
18.1 |
908 |
474 |
21.6 |
1089 |
655 |
26.8 |
1947 |
1510 |
2*50 |
20.4 |
1253 |
633 |
24.4 |
1460 |
841 |
29.0 |
2438 |
1814 |
2*70 |
23.0 |
1670 |
803 |
26.8 |
1900 |
1032 |
31.8 |
3389 |
2515 |
2*95 |
24.4 |
2219 |
1042 |
30.2 |
2493 |
1316 |
35.6 |
4109 |
2923 |
2*120 |
28.7 |
2728 |
1242 |
33.6 |
3332 |
1845 |
37.8 |
4847 |
3350 |
2*150 |
31.8 |
3372 |
1513 |
37.0 |
4056 |
2198 |
42.1 |
6332 |
4461 |
2*185 |
35.2 |
4163 |
1871 |
40.6 |
4927 |
2635 |
46.5 |
7430 |
5121 |
0.6/1kV 3-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
3*4 |
14.4 |
299 |
225 |
16.8 |
439 |
365 |
/ |
/ |
/ |
3*6 |
15.5 |
376 |
264 |
17.9 |
526 |
414 |
/ |
/ |
/ |
3*10 |
18.3 |
545 |
359 |
20.7 |
722 |
536 |
/ |
/ |
/ |
3*16 |
20.6 |
757 |
460 |
23.0 |
956 |
658 |
/ |
/ |
/ |
3*25 |
20.2 |
857 |
485 |
22.6 |
1052 |
680 |
28.0 |
1955 |
1487 |
3*35 |
22.0 |
1298 |
647 |
24.4 |
1510 |
859 |
27.3 |
2171 |
1516 |
3*50 |
25.3 |
1794 |
865 |
27.9 |
2050 |
1121 |
30.6 |
2761 |
1825 |
3*70 |
28.5 |
2426 |
1125 |
30.9 |
2697 |
1397 |
34.8 |
3811 |
2500 |
3*95 |
32.3 |
3233 |
1468 |
36.1 |
3897 |
2132 |
38.3 |
4734 |
2956 |
3*120 |
35.1 |
3990 |
1760 |
38.9 |
4710 |
2479 |
43.4 |
6178 |
3931 |
3*150 |
38.8 |
4949 |
2161 |
42.8 |
5761 |
2973 |
47.6 |
7403 |
4596 |
3*185 |
42.9 |
6078 |
2640 |
47.1 |
6985 |
3547 |
52.1 |
8804 |
5341 |
3*240 |
48.1 |
7807 |
3347 |
52.3 |
8821 |
4361 |
57.3 |
10747 |
6255 |
3*300 |
53.0 |
9676 |
4100 |
57.2 |
10788 |
5213 |
61.9 |
12822 |
7206 |
0.6/1kV 3+1-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
3*4+1*2.5 |
14.6 |
328 |
239 |
16.8 |
470 |
380 |
/ |
/ |
/ |
3*6+1*4 |
16.1 |
428 |
292 |
17.9 |
583 |
447 |
/ |
/ |
/ |
3*10+1*6 |
18.7 |
614 |
391 |
20.7 |
795 |
572 |
/ |
/ |
/ |
3*16+1*10 |
21.4 |
876 |
516 |
23.0 |
1082 |
722 |
/ |
/ |
/ |
3*25+1*16 |
21.1 |
1202 |
638 |
24.2 |
1405 |
842 |
26.1 |
2349 |
1782 |
3*35+1*16 |
23.3 |
1524 |
775 |
25.9 |
1749 |
999 |
29.6 |
2606 |
1852 |
3*50+1*25 |
27.1 |
2147 |
1063 |
30.5 |
2406 |
1322 |
34.8 |
3609 |
2524 |
3*70+1*35 |
30.3 |
2871 |
1353 |
33.9 |
3175 |
1657 |
38.2 |
4606 |
3077 |
3*95+1*50 |
34.8 |
3868 |
1793 |
38.5 |
4580 |
2505 |
42.6 |
5794 |
3704 |
3*120+1*70 |
37.6 |
4825 |
2162 |
41.8 |
5592 |
2929 |
47.9 |
7540 |
4857 |
3*150+1*70 |
41.7 |
5806 |
2584 |
45.0 |
6655 |
3434 |
52.1 |
8850 |
5605 |
3*185+1*95 |
46.2 |
7214 |
3187 |
49.9 |
8190 |
4163 |
57.0 |
10563 |
6507 |
3*240+1*120 |
51.8 |
9197 |
3993 |
55.5 |
10286 |
5082 |
62.4 |
12940 |
7700 |
3*300+1*150 |
57.3 |
11415 |
4910 |
61.2 |
12616 |
6111 |
72.8 |
16296 |
9744 |
0.6/1kV 4-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
4*4 |
15.2 |
355 |
256 |
17.6 |
501 |
402 |
/ |
/ |
/ |
4*6 |
16.4 |
453 |
305 |
18.8 |
612 |
463 |
/ |
/ |
/ |
4*10 |
19.5 |
670 |
422 |
21.9 |
858 |
610 |
/ |
/ |
/ |
4*16 |
22.1 |
947 |
550 |
24.5 |
1159 |
762 |
/ |
/ |
/ |
4*25 |
22.7 |
1322 |
703 |
25.1 |
1540 |
921 |
30.3 |
2316 |
1801 |
4*35 |
24.9 |
1729 |
862 |
27.5 |
1981 |
1114 |
29.6 |
2615 |
1741 |
4*50 |
28.7 |
2398 |
1159 |
31.3 |
2687 |
1448 |
34.2 |
3648 |
2400 |
4*70 |
32.3 |
3221 |
1487 |
36.1 |
3883 |
2149 |
38.1 |
4682 |
2935 |
4*95 |
36.8 |
4290 |
1936 |
40.8 |
5062 |
2708 |
42.5 |
5917 |
3818 |
4*120 |
39.8 |
5277 |
2303 |
43.8 |
6110 |
3137 |
47.8 |
7643 |
4648 |
4*150 |
44.4 |
6567 |
2850 |
48.2 |
7469 |
3752 |
52.2 |
9164 |
5420 |
4*185 |
49.0 |
8062 |
3478 |
53.2 |
9094 |
4509 |
57.1 |
10905 |
6288 |
4*240 |
54.9 |
10334 |
4387 |
59.1 |
11488 |
5541 |
62.9 |
13466 |
7476 |
4*300 |
60.7 |
12811 |
5377 |
64.9 |
14082 |
6648 |
69.1 |
16480 |
9040 |
0.6/1kV 4-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
4*4 |
15.2 |
355 |
256 |
17.6 |
501 |
402 |
/ |
/ |
/ |
4*6 |
16.4 |
453 |
305 |
18.8 |
612 |
463 |
/ |
/ |
/ |
4*10 |
19.5 |
670 |
422 |
21.9 |
858 |
610 |
/ |
/ |
/ |
4*16 |
22.1 |
947 |
550 |
24.5 |
1159 |
762 |
/ |
/ |
/ |
4*25 |
22.7 |
1322 |
703 |
25.1 |
1540 |
921 |
30.3 |
2316 |
1801 |
4*35 |
24.9 |
1729 |
862 |
27.5 |
1981 |
1114 |
29.6 |
2615 |
1741 |
4*50 |
28.7 |
2398 |
1159 |
31.3 |
2687 |
1448 |
34.2 |
3648 |
2400 |
4*70 |
32.3 |
3221 |
1487 |
36.1 |
3883 |
2149 |
38.1 |
4682 |
2935 |
4*95 |
36.8 |
4290 |
1936 |
40.8 |
5062 |
2708 |
42.5 |
5917 |
3818 |
4*120 |
39.8 |
5277 |
2303 |
43.8 |
6110 |
3137 |
47.8 |
7643 |
4648 |
4*150 |
44.4 |
6567 |
2850 |
48.2 |
7469 |
3752 |
52.2 |
9164 |
5420 |
4*185 |
49.0 |
8062 |
3478 |
53.2 |
9094 |
4509 |
57.1 |
10905 |
6288 |
4*240 |
54.9 |
10334 |
4387 |
59.1 |
11488 |
5541 |
62.9 |
13466 |
7476 |
4*300 |
60.7 |
12811 |
5377 |
64.9 |
14082 |
6648 |
69.1 |
16480 |
9040 |
0.6/1kV 3+2-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
3*4+2*1.5 |
14.3 |
324 |
218 |
17.5 |
508 |
401 |
/ |
/ |
/ |
3*6+2*4 |
16.1 |
440 |
277 |
19.3 |
646 |
482 |
/ |
/ |
/ |
3*10+2*6 |
18.7 |
635 |
370 |
21.9 |
873 |
607 |
/ |
/ |
/ |
3*16+2*10 |
21.8 |
926 |
499 |
25.0 |
1203 |
775 |
/ |
/ |
/ |
3*25+2*16 |
23.3 |
1333 |
664 |
26.1 |
1585 |
916 |
30.8 |
2459 |
1791 |
3*35+2*16 |
24.7 |
1635 |
784 |
27.7 |
1914 |
1063 |
32.7 |
2710 |
1855 |
3*50+2*25 |
28.3 |
2255 |
1063 |
32.5 |
2924 |
1732 |
36.3 |
3952 |
2704 |
3*70+2*35 |
32.0 |
3135 |
1407 |
36.2 |
3883 |
2155 |
39.8 |
4933 |
3186 |
3*95+2*50 |
36.7 |
4217 |
1866 |
41.1 |
5092 |
2742 |
44.0 |
6223 |
3821 |
3*120+2*70 |
40.7 |
5417 |
2329 |
44.9 |
6360 |
3272 |
50.1 |
8240 |
5994 |
3*150+2*70 |
43.7 |
6303 |
2694 |
47.9 |
7314 |
3705 |
53.1 |
9382 |
5700 |
3*185+2*95 |
49.2 |
8024 |
3413 |
53.4 |
9161 |
4549 |
58.4 |
11327 |
6678 |
3*240+2*120 |
55.0 |
10314 |
4315 |
59.2 |
11580 |
5581 |
64.0 |
13850 |
7860 |
3*300+2*150 |
60.8 |
12817 |
5322 |
65.0 |
14212 |
6717 |
69.9 |
16710 |
9223 |
0.6/1kV 4+1-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
4*4+1*2.5 |
14.8 |
348 |
232 |
18.0 |
537 |
421 |
/ |
/ |
/ |
4*6+1*4 |
16.4 |
465 |
289 |
19.6 |
673 |
496 |
/ |
/ |
/ |
4*10+1*6 |
19.4 |
686 |
396 |
22.6 |
932 |
641 |
/ |
/ |
/ |
4*16+1*10 |
22.4 |
992 |
528 |
25.5 |
1275 |
809 |
/ |
/ |
/ |
4*25+1*16 |
23.5 |
1362 |
638 |
26.1 |
1609 |
885 |
30.1 |
2513 |
1789 |
4*35+1*16 |
25.1 |
1751 |
777 |
27.7 |
2009 |
1035 |
31.9 |
2970 |
1997 |
4*50+1*25 |
29.5 |
2473 |
1069 |
33.5 |
3104 |
1700 |
37.5 |
4244 |
2840 |
4*70+1*35 |
32.9 |
3367 |
1402 |
37.1 |
4083 |
2117 |
40.9 |
5322 |
3357 |
4*95+1*50 |
37.3 |
4512 |
1829 |
41.3 |
5301 |
2618 |
46.8 |
7266 |
4583 |
4*120+1*70 |
41.2 |
5709 |
2277 |
45.2 |
6578 |
3146 |
50.7 |
8747 |
5316 |
4*150+1*70 |
45.1 |
6921 |
2740 |
49.1 |
7871 |
3690 |
54.8 |
10264 |
6084 |
4*185+1*95 |
49.8 |
8592 |
3382 |
53.8 |
9637 |
4427 |
60.3 |
12340 |
7215 |
4*240+1*120 |
56.2 |
11018 |
4279 |
60.2 |
12193 |
5454 |
66.3 |
15140 |
8401 |
0.6/1kV 5-core XLPE insulation PVC sheath power cable
Nominal Area mm2 |
Non armored |
Tape-armored |
Wire-armored |
||||||
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
Reference diameter mm |
Approximate weight kg/km |
||||
YJV |
YJLV |
YJV22 |
YJLV22 |
YJV32 |
YJLV32 |
||||
5*2.5 |
13.4 |
266 |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
5*4 |
14.6 |
386 |
260 |
18.3 |
570 |
446 |
/ |
/ |
/ |
5*6 |
16.0 |
505 |
316 |
19.7 |
704 |
517 |
/ |
/ |
/ |
5*10 |
19.1 |
760 |
433 |
23.5 |
999 |
684 |
27.0 |
1700 |
1390 |
5*16 |
22.6 |
1090 |
588 |
26.0 |
1357 |
858 |
30.0 |
2316 |
1820 |
5*25 |
27.4 |
1598 |
818 |
31.0 |
2183 |
1390 |
35.0 |
2848 |
2073 |
5*35 |
30.5 |
2134 |
1049 |
34.5 |
2764 |
1664 |
38.2 |
3648 |
2563 |
5*50 |
33.0 |
2848 |
1382 |
37.4 |
3594 |
2105 |
41.5 |
4682 |
3132 |
5*70 |
37.0 |
3980 |
1823 |
41.9 |
4849 |
2658 |
47.8 |
5917 |
3747 |
5*95 |
43.7 |
5386 |
2447 |
49.0 |
6834 |
3848 |
55.0 |
7843 |
4898 |
1.Quickly and professional response
2. 20+ imports and export experiences
3. Excellent quality with reasonable price.
4. Sufficient support for our tendering representatives.
5. OEM service available based on official & legal authorization.
6. Strict quality control system.
7. Faster lead time than our competitors.
8. Cable solutions to your particular requirements.
9. Free sample is available with economic express fee.
10.12 months quality guarantee after delivery.
How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..
What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.
What's the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement
What's the lead time?
Usually 10-30 working days.