Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Building, House
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 1/Meter
Request Sample
Manufacturer/Factory, Trading Company, Other
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100 RMB
Plant Area
101~500 square meters
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
  • Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Workshop
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
ABC
Insulation Material
PVC, PE, XLPE
Sheath Material
-
Material Shape
Round Wire
Wire Core Material
Aluminium, Aluminum Alloy, Bare Copper
Certification
ISO, CCC, CE, RoHS
Model
Jkv, Jklv
Brand
Qif
Insulation Color
Customized
Min Quantity
1000m
Conductor Grade
1350-H19, 6208-T81
Service
OEM ODM
Packing Size
100m/Roll, 305m/Roll, Wrap Plastic Film Packaging
Transport Package
Coil/Spool/Carton/Pallet/
Specification
multi-core
Trademark
QIF
Origin
China
HS Code
85444929
Production Capacity
500000m/Month

Product Description

Product Description
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable

Construction

Conductor: Aluminium conductor, round stranded compressed (RM).
Insulation: XPLE compound, UV-resistant.
Core Identification: 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth.


Electrical Properties

Rated Voltage: 0.6/1kV
Test Voltage: 4 Veff kV
Minimum Laying Temperature: -20°C
Operating Temperature: -40°C~ +90°C
Maximum Short-circuit Temperature: 250°C
Maximum Conductor Temperature: 80°C
Minimum Bending Radius: 18×OD


Application

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.


Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Product Parameters
BS   7870
NUMBER OF CORES X NOMINAL CROSS SECTION OVERALL DIAMETER WEIGHT MAXIMUM CONDUCTOR RESISTANCE MINIMUM BREAKING LOAD CURRENT RATING
NO./MM2 MM KG/KM Ω/KM KN A
1x16  8 74 1.91 2.5 72
1x25  9 106 1.2 4 107
1x35  10.5 138 0.868 5.5 132
1x50  11.8 182 0.641 8 165
1x70  13 252 0.443 10.7 205
1x95  15.4 333 0.32 13.7 240
1x120  17 408 0.253 18.6 290
1x150  19 502 0.206 23.2 334
1x185  21 611 0.164 28.7 389
1x240  24 801 0.125 37.2 467
2x16  15.6 147 1.91 2.5 72
2x25  18 208 1.2 4 107
2x35  20 277 0.868 5.5 132
2x50  23.5 361 0.641 8 165
2x70  25.4 505 0.443 10.7 205
2x95  30.3 666 0.32 13.7 240
2x150  38 1004 0.206 23.2 334
4x16  18.8 286 1.91 2.5 72
4x25  21.2 430 1.2 4 107
4x35  24.1 553 0.868 5.5 132
4x50  27.8 746 0.641 8 165
4x70  31.8 1009 0.443 10.7 205
4x95  37.8 1332 0.32 13.7 240
4x120  54.4 1632 0.253 18.6 290
4x50 + 1x25  31.9 814 0.641/1.200 8.0/4.0 165/107
4x50 + 1x35  31.9 845 0.641/0.868 8.5/5.5 165/132
4x70 + 1x25  36 1105 0.443/1.200 10.7/4.0 205/107
4x70 + 2x25  40 1217 0.443/1.200 10.7/4.0 205/107
4x95 + 1x25  41.8 1438 0.320/1.200 13.7/4.0 240/107
4x95 + 2x25  42 1544 0.320/1.200 13.7/4.0 240/107
4x120 + 1x25  59 2050 0.253/1.200 18.6/4.0 290/107
Note: Other cross-sections can be offered upon request.
 
TNB SPECIFICATION(IEC 60502)
NUMBER OF CORES X NOMINAL CROSS SECTION OVERAL DIAMETER WEIGHT MAXIMUM CONDUCTOR RESISTANCE MINIMUM BREAKING LOAD CURRENT RATING
NO./MM2 MM KG/KM Ω/KM KN A
1x16+1x25  15.3 160 1.91 2.5 72
3x16+1x25  19 290 1.2 4 107
3x25+1x25  23.2 400 0.868 5.5 132
3x35+1x25  25.6 500 0.641 8 165
3x50+1x35  30 680 0.443 10.7 205
3x70+1x50  34.9 920 0.32 13.7 240
3x95+1x70  40.6 1270 0.253 18.6 290
3x120+1x70  44.1 1510 0.206 23.2 334
3x150+1x95  49.2 1870 0.164 28.7 389
3x185+1x120  54.9 2340 0.125 37.2 467
3x25+1x25+1x16  23.2 470 1.91 2.5 72
3x35+1x25+1x16  25.6 560 1.2 4 107
3x50+1x35+1x16  30 740 0.868 5.5 132
3x70+1x50+1x16  34.9 980 0.641 8 165
3x95+1x70+1x16  40.6 1330 0.443 10.7 205
3x120+1x70+1x16  44.1 1580 0.32 13.7 240
3x150+1x95+1x16  49.2 1940 0.206 23.2 334
3x185+1x120+1x16  54.9 2410 0.106 30.8 332
Note: Other cross-sections can be offered upon request.
 
HD 626 S1
NUMBER OF CORES X NOMINAL CROSS SECTION OUTER DIAMETER TOTAL WEIGHT MAX. CONDUCTOR- RESISTANCE MIN. BREAKING LOAD OF CONDUCTOR STRAND CURRENT RATING IN THE AIR 1)
No./MM2 CA. MM CA. KG/KM OHM/KM KN A
2x16  14.2 72 147 1.91 2,5
2x25  17.2 107 208 1.2 4
2x35  19.6 132 277 0.868 5.5
2x50  22.4 165 361 0.641 8
4x16  17.6 72 286 1.91 2.5
4x25  20.3 107 430 1.2 4
4x35  23.7 132 553 0.868 5.5
4x50  27.1 165 746 0.641 8
4x70  30.6 205 1009 0.443 10.7
4x95  36.1 240 1332 0.32 13.7
4x120  51.2 290 1632 0.253 18.6
4x35 + 1x35  27.4 132/132 694 0.868/0.868 5.5/5.5
4x50 + 1x25  30.5 165/107 814 0.641/1.200 8.0/4.0
4x50 + 1x35  30.7 165/132 845 0.641/0.868 8.5/5.5
4x70 + 1x25  34.8 205/107 1105 0.443/1.200 10.7/4.0
4x70 + 2x25  38.7 205/107 1217 0.443/1.200 10.7/4.0
4x70 + 1x35  36 205/132 1150 0.443/0.868 10.7/5.5
4x70 + 2x35  38.2 205/132 1289 0.443/0.868 10.7/5.5
4x95 + 1x25  40.2 240/107 1438 0.320/1.200 13.7/4.0
4x95 + 1x35  42.1 240/132 1467 0.320/0.868 13.7/5.5
4x95 + 2x25  40.9 240/107 1544 0.320/1.200 13.7/4.0
Note: Other cross-sections can be offered upon request.
 
NFC 33-209
NUMBER OF CORES X NOMINAL CROSS SECTION OVERAL DIAMETER WEIGHT MAXIMUM CONDUCTOR RESISTANCE MINIMUM BREAKING LOAD CURRENT RATING
NO./MM2 MM KG/KM Ω/KM KN A
2x10 RM 12.8 93 3.08 1.5 38
4x10 RM 15.4 183 3.08 1.5 38
2x16 RM 14.8 129 1.91 2.3 72
2x16 RN + 2x1.5 RE 14.8 176 1.910/12.100 2.3 72
4x16 RM 17.8 257 1.91 2.3 72
4x16 RN + 2x1.5 RE 17.8 304 1.910/12.100 2.3 72
2x25 RM 18 202 1.2 3.8 107
2x25 RM + 2x1.5 RE 18 249 1.200/12.100 3.8 107
4x25 RM 21.7 404 1.2 3.8 107
4x25 RM + 2x1.5 RE 21.7 451 1.200/12.100 3.8 107
2x35 RM 20.8 269 0.868 5.2 132
2x35 RM + 2x1.5 RE 20.8 316 0.868/12.100 5.2 132
4x35 RM 25.1 539 0.868 5.2 132
4x35 RM + 2x1.5 RE 25.1 586 0.868/12.100 5.2 132
2x50 RM 23.4 352 0.641 7.6 165
2x50 RM + 2x1.5 RE 23.4 399 0.641/12.100 7.6 165
1x54.6 RM + 3x25 RM 21.7 507 0.630/1.200 3.8 107
1x54.6 RM + 3x25 RM + 1x16 RM 24.3 573 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 2x16 RM 29.7 639 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 3x16 RM 31.1 705 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x35 RM 25.1 615 0.630/0.868 5.2 132
1x54.6 RM + 3x35 RM + 1x16 RM 28.1 680 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 2x16 RM 34.3 748 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 3x16 RM 35.9 814 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 1x25 RM 28.1 714 0.630/0.868/1.200 5.2/3.8 132/107
1x54.6 RM + 3x50 RM 28.2 741 0.630/0.641 7.6 165
1x54.6 RM + 3x50 RM + 1x16 RM 31.6 806 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 2x16 RM 38.6 875 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 3x16 RM 40.4 940 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 1x25 RM 31.6 841 0.630/0.641/1.200 7.6/3.8 165/107
1x54.6 RM + 3x70 RM 33 950 0.630/0.443 10.2 205
1x54.6 RM + 3x70 RM + 1x16 RM 37 1014 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 2x16 RM 45.2 1083 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 3x16 RM 47.3 1148 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 1x25 RM 37 1048 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 2x25 RM 45.2 1150 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 3x25 RM 47.3 1250 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x95 RM 37.4 1176 0.630/0.320 13.5 240
1x54.6 RM + 3x95 RM + 1x16 RM 41.9 1243 0.630/0.320/1.910 13.5/2.3 240/72
Note: Other cross-sections can be offered upon request.
 
AS/NZS 3560 PART 1  
NUMBER OF CORES X NOMINAL CROSS SECTION OVERALL DIAMETER WEIGHT MINIMUM BREAKING LOAD CURRENT RATING  
NO./MM2 MM KG/KM KN A  
2x16  15 140 4.4 78  
2x25  17.6 210 7 105  
2x35  19.6 270 9.8 125  
2x50  22.8 370 11.4 150  
2x95  30.6 680 15.3 230  
3x25  19 310 8.8 97  
3x35  21.1 410 9.8 120  
3x50  24.6 550 11.4 140  
4x16  18.1 290 8.8 74  
4x25  21.2 410 14 97  
4x35  23.7 550 19.6 120  
4x50  27.5 740 28 140  
4x70  31.9 1000 39.2 175  
4x95  36.9 1370 53.2 215  
4x120  40.6 1690 67.2 250  
4x150  43.9 2020 84 280  
Note: Other cross-sections can be offered upon request.
 
Workshop

 

Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
 
Packaging & Shipping
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable
Wholesale Supplier China Product 600V XLPE Insulation ABC Cable and Overhead Twisted Cable

 

FAQ

 

How can I get some samples?

We provide free sample and will courier to you by DHL, FEDEX, UPS, TNT, etc. swiftly according to your requirements.


How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.   
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..

What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.


What's the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement

What's the lead time?
Usually 10-30 working days.

Welcome your inquiry and email soon......

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier