Type of cable | Minimum Bending Radius (mm) | |
During Installation | Adjacent to joints or terminals | |
Single Core Cables | 15D | 12D |
Three Core Cables | 12D | 10D |
Conductor
Class 2 stranded circular or circular compacted
Semi-Conductive Layer for Conductor
Semi-conductive material
Insulation
XLPE (Cross-Linked Polyethylene)
Semi-Conductive Layer for Insulation
Semi-conductive material
Metallic screen
Copper wires / Copper Tape / Copper Wire & Tape
Outer Sheath
PVC (Polyvinyl Chloride)
The conductor Semi-Conductive Layer, XLPE insulation and the insulation Semi-Conductive Layer are extruded simultaneously in one process using triple extrusion method (Continuous Vulcanization Line). Triple extrusion method not only assures clean interfaces between the insulation and stress control layers, but also assures a construction free of Partial Discharge with high operational reliability.
The Main Technical Parameter Of The Cable
1) Cable conductor DC resistance: See the table 1-1
2) Partial discharge test: See the table 1-2
3) AC voltage test: See the table 1-3
4) Rated Voltage,Core Numbers & Nominal Cross-section Area : See the table1-4
Table 1-1 Max. DC resistance of cable conductor at 200C
Rated cross area (mm2) |
16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | |
Cu (Ω/km) |
Non tinned | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 |
Tinned | 1.16 | 0.734 | 0.529 | 0.391 | 0.270 | 0.195 | 0.154 | 0.126 | |
Al (Ω/km) | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | |
Rated cross area (mm2) |
185 | 240 | 300 | 400 | 500 | 630 | 800 | 1000 | |
Cu (Ω/km) |
Non tinned | 0.0991 | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 |
Tinned | 0.100 | 0.0762 | 0.0607 | 0.0475 | 0.0369 | 0.0286 | 0.0224 | 0.0177 | |
Al ( Ω/km) | 0.164 | 0.125 | 0.100 | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 |
Rated Voltage (kV) |
3.6/6 | 6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage (kV) |
6.23 | 10.38 | 15.05 | 20.76 | 31.14 | 36.33 | 44.98 |
Discharge capacity (pC) |
10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated Voltage kV |
3.6/6 3.6/10 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage kV |
12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test Time min |
5 | 5 | 5 | 5 | 5 | 5 | 5 |
U0/Um Area mm2 | 3.6/6 | 6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/20 18/30 |
21/35 | 26/35 | |
Core No. | 1 | 25-630 | 25-630 | 35-630 | 35-630 | 50-630 | 50-630 | 50-630 |
3 | 25-400 | 25-400 | 35-400 | 35-400 | 50-400 | 50-400 | 50-400 |
How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..
What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.
What's the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement
What's the lead time?
Usually 10-30 working days.
Welcome your inquiry and email soon......